二手 RIGAKU 3640 #9200622 待售
網址複製成功!
單擊可縮放
ID: 9200622
晶圓大小: 8"
優質的: 2009
X-Ray fluorescence wafer / Disk analyzer, 8"
Size: Less 1m²
Silicon wafer: WSix
Functions:
Multi-job
Multi-window
Multi-point distribution measurement:
Sample surface: 100 Arbitrary positions
Monitor display
Area sensor and protection mechanism of sample chamber lid
Specification:
Single layer film: BPSG, SiO2, WSix, polysilicon, W, TiN, AlSiCu, PZT, Y1 and BST on Si wafers, and oxide
Metal and alloy film such as glass and ceramic
Multi-layer film: Ti / Ni / Au on Si wafers
Compound film: Co alloy / Cr / Ni-P on memory disks
Sample chamber:
Sample size: 200 mm Diameter maximum
Collimator:
Center measurement: Out
Measurement: In (15 mm - 20 mm Diameter)
Movement: XYD Driving system
Goniometer
Counting unit:
Counting method: Multi-element
Counting capacity: 1.3 × 108 Counts
Counting time: 1 - 999 sec (Presettable at an interval of 1 second)
X-Ray generator unit:
Output: 3 kVA
Stability: Within +/-0.01%
X-Ray tube:
Capacity: 3 kW
Target: Rh
Heat Exchanger: Pure water circulation method
Evacuation system:
Dry pump: KASHIYAMA MU100N
Temperature stabilizer:
Control temperature: 36.5 +/-0.2°C (Vicinity of the sensor)
Computer system:
Computer: Windows type personal computer
Auxiliary memories:
Hard disk
Floppy disk: 1.44 MB × 1 (3.5")
CD-ROM
Monitor: LCD
Printer: A4 Size ink jet printer
Standard accessories:
Tools
Lamps
Fuses
Oils and greases
Data capacity:
Quantitative analysis:
Measuring condition: 300
Process parameter formula:
40 Calculation terms / Formula
300 Formulae
Calibration curve: 2000 Components
Group condition:
40 Components*1 / Group
200 Groups
Drift correction sample: 200
Limit range check: 40 Components*1 / Standard 500 standards
Standard sample:
40 Elements / Sample
500 Samples
Bias correction sample: 300
Calibration: Up to 200 - 40 constants sample
Record of analysis results: 2000 Sample IDs / 10000 Measurement points
Qualitative analysis:
Measuring condition: 300
Group condition:
30 Conditions / Groups
50 Groups
Configuration of options:
Additional instruction manual: English, dust-free paper
Additional instruction manual: English, plain paper
2-Theta table: English and japanese, plain paper
Sample holder: 200 mm in Diameter
Sample holder (With adapter): 30 mm in Diameter
X-Ray indicator: With interlock function
Power: 3 Phase, 200 VAC, 75 A, 50/60 Hz.
RIGAKU 3640是用於射線照相應用的先進X射線設備。它是一個兩軸旋轉的全身X射線系統,在X射線成像中提供增強的覆蓋範圍和精度。該單元具有可調節X射線光束高度和可旋轉控制臂的全身機櫃。該設計允許在使用更廣泛的X射線照射的同時進行符合人體工程學的操作。該機器還具有高度敏感的數字面板,可以快速更新您的最新圖像信息。3640具有安全高效的X射線工具,內置保護功能,可確保精確成像,同時提供高分辨率圖像。安全部件包括一個屏蔽室,用於過濾設備可能發出的任何雜散和有害的X射線輻射。此外,資產還具有許多預設的安全功能,可以快速識別可能導致膠片過度曝光的用戶錯誤。該型號還配備了一個可調節的桌子,以確保放射成像患者的最佳定位。RIGAKU 3640上的X射線發生器提供了截止濾波器,允許用戶控制X射線強度的水平,以避免過度曝光。該濾波器還提供用戶對輻照度的控制,這對於手部和四肢成像特別有用。此外,該設備先進的X射線源提供了廣泛的電壓範圍與陽極氧化銅過濾改善對比度和分辨率。3640利用了直接數字射線照相(DDR)系統,包括圖像處理站和集成圖像質量保證(IQA)程序。此單元允許精確的射線成像,同時消除了與開發X射線相關的傳統體力勞動。DDR機器允許用戶在比傳統放射照相方法更短的時間內產生更高質量的圖像。RIGAKU 3640還提供各種曝光設置和射線照相對比度。該工具可以產生各種各樣的膠片選擇和組合,以滿足臨床和工業應用的放射線照相需求。對比度水平和曝光設置可以很容易地調整,以便在各種情況下提供理想的圖像。總體而言,3640是用於射線照相應用的高度可靠和高效的成像資產。它具有多種保護和安全功能,可確保精確成像,並具有直接數字射線照相(DDR)模型以提高效率。該設備還提供了廣泛的曝光設置和對比度級別,以便在各種應用程序中實現最大的靈活性。
還沒有評論